Roseville
Placer County, California · EIA plant ID 7452 · Operator: City of Roseville - (CA)
Nameplate66MWSummer 42 MW
Generators2in service
Net generation1GWh12 mo to Dec 2025
Capacity factor0%gas/coal/oil units, summer MW
Heat rate27,334Btu/kWhfossil units, electric fuel, HHV
First online1986Runs as rarely runs
Monthly net generation
EIA-923, all units at the plant. Net of station use; storage can go negative.
FinalPreliminary
Capacity factor by year
Net MWh ÷ (summer MW × hours), gas/coal/oil units. Each year uses that year's EIA-860 ratings; the hollow dot is the latest 12 months.
Heat rate by year
Electric fuel MMBtu × 1000 ÷ net MWh (Btu/kWh, HHV), fossil units only; CT + CA counted as one combined-cycle block.
Annual data table
| Year | Net GWh | Capacity factor | Heat rate (Btu/kWh) |
|---|---|---|---|
| 2002 | 4.8 | 1.1% | 14,473 |
| 2003 | 13.5 | 48.1% | 10,682 |
| 2004 | 1.1 | 0.3% | 28,553 |
| 2005 | 1.3 | 0.3% | 15,973 |
| 2006 | 4.2 | 1.1% | 14,934 |
| 2007 | 1.6 | 0.4% | 17,408 |
| 2008 | 1.7 | 0.4% | 16,740 |
| 2009 | 0.9 | 0.3% | 16,675 |
| 2010 | 0.7 | 0.2% | 16,650 |
| 2011 | 0.9 | 0.3% | 15,879 |
| 2012 | 1.6 | 0.4% | 15,416 |
| 2013 | 0.9 | 0.2% | 20,661 |
| 2014 | 0.6 | 0.2% | 17,893 |
| 2015 | 2.5 | 0.7% | 15,856 |
| 2016 | 1 | 0.3% | 16,060 |
| 2017 | 1.3 | 0.4% | 16,133 |
| 2018 | 3 | 0.8% | 15,238 |
| 2019 | 1.4 | 0.4% | 19,467 |
| 2020 | 2.3 | 0.6% | 16,647 |
| 2021 | 10.2 | 2.7% | 16,577 |
| 2022 | 5.8 | 1.6% | 17,635 |
| 2023 | 4 | 1.1% | 18,848 |
| 2024 | 6.9 | 1.8% | 17,172 |
| 2025 | 0.6 | 0.1% | 27,334 |
Fuel capability
Gas-fired turbines (CT/GT/CA/CS) that can also burn liquid fuel. EIA-860 Schedule 3 for capability, EIA-923 for actual burn.
StatusLikely still dual fuel
Liquid fuel burned · 36 mo146 MMBtu
Last month with liquid burnDec 2025
Switch while operating—
Net summer MW on gas—
Net summer MW on oil—
Time gas → oil—
Time oil → gas—
⚠ EIA-860 vs 923: 923 shows liquid fuel burn in gas turbines but 860 lists no oil capability.
Generators
EIA-860 (annual) with EIA-860M updates through Sep 2026. EIA-923 reports generation by plant, prime mover and fuel, not by unit, so unit-level output isn't shown.
| Gen ID | Technology | Prime mover | Nameplate MW | Summer MW | Online | Status | Planned retirement | OEM / model |
|---|---|---|---|---|---|---|---|---|
| 1 | Natural Gas Fired Combustion Turbine | GT | 33 | 21.2 | Apr 1986 | Operating (Standby / backup) | — | coming soon |
| 2 | Natural Gas Fired Combustion Turbine | GT | 33 | 21.2 | May 1986 | Operating (Standby / backup) | — | coming soon |
Owner / operator
Operator: City of Roseville - (CA). Ownership shares by in-service nameplate MW (EIA-860 Schedule 4; units not listed there are wholly owned by the operator).
| City of Roseville - (CA) | 100.0% | 66 MW |
Nearby plants
Within 80 km.
| Rio Bravo Rocklin | 28 MW | 2.5 km |
| Pivot Energy PPA 29 LLC | — | 2.6 km |
| Lincoln Landfill | 5 MW | 3.4 km |
| Roseville Energy Park | 225 MW | 5.3 km |
| Lincoln WWTF Hybrid | 4 MW | 5.7 km |
| Sierra Pacific Lincoln Facility | 19 MW | 10.4 km |