← Back to map

Roseville

Placer County, California · EIA plant ID 7452 · Operator: City of Roseville - (CA)
Natural gasNatural Gas Fired Combustion Turbine⛽ Dual-fuelCAISOBA: BANC
Nameplate66MWSummer 42 MW
Generators2in service
Net generation1GWh12 mo to Dec 2025
Capacity factor0%gas/coal/oil units, summer MW
Heat rate27,334Btu/kWhfossil units, electric fuel, HHV
First online1986Runs as rarely runs

Monthly net generation

EIA-923, all units at the plant. Net of station use; storage can go negative.
FinalPreliminary
0246GWh200220042006200820102012201420162018202020222024

Capacity factor by year

Net MWh ÷ (summer MW × hours), gas/coal/oil units. Each year uses that year's EIA-860 ratings; the hollow dot is the latest 12 months.
0%20%40%200520102015202020250.2% · 12 mo

Heat rate by year

Electric fuel MMBtu × 1000 ÷ net MWh (Btu/kWh, HHV), fossil units only; CT + CA counted as one combined-cycle block.
010,00020,00030,0002005201020152020202527,334 Btu/kWh · 12 mo
Annual data table
YearNet GWhCapacity factorHeat rate (Btu/kWh)
20024.81.1%14,473
200313.548.1%10,682
20041.10.3%28,553
20051.30.3%15,973
20064.21.1%14,934
20071.60.4%17,408
20081.70.4%16,740
20090.90.3%16,675
20100.70.2%16,650
20110.90.3%15,879
20121.60.4%15,416
20130.90.2%20,661
20140.60.2%17,893
20152.50.7%15,856
201610.3%16,060
20171.30.4%16,133
201830.8%15,238
20191.40.4%19,467
20202.30.6%16,647
202110.22.7%16,577
20225.81.6%17,635
202341.1%18,848
20246.91.8%17,172
20250.60.1%27,334

Fuel capability

Gas-fired turbines (CT/GT/CA/CS) that can also burn liquid fuel. EIA-860 Schedule 3 for capability, EIA-923 for actual burn.
StatusLikely still dual fuel
Liquid fuel burned · 36 mo146 MMBtu
Last month with liquid burnDec 2025
Switch while operating—
Net summer MW on gas—
Net summer MW on oil—
Time gas → oil—
Time oil → gas—

⚠ EIA-860 vs 923: 923 shows liquid fuel burn in gas turbines but 860 lists no oil capability.

Generators

EIA-860 (annual) with EIA-860M updates through Sep 2026. EIA-923 reports generation by plant, prime mover and fuel, not by unit, so unit-level output isn't shown.
Gen IDTechnologyPrime moverNameplate MWSummer MWOnlineStatusPlanned retirementOEM / model
1Natural Gas Fired Combustion TurbineGT3321.2Apr 1986Operating (Standby / backup)—coming soon
2Natural Gas Fired Combustion TurbineGT3321.2May 1986Operating (Standby / backup)—coming soon

Owner / operator

Operator: City of Roseville - (CA). Ownership shares by in-service nameplate MW (EIA-860 Schedule 4; units not listed there are wholly owned by the operator).
City of Roseville - (CA)100.0%66 MW

Nearby plants

Within 80 km.
Rio Bravo Rocklin28 MW2.5 km
Pivot Energy PPA 29 LLC—2.6 km
Lincoln Landfill5 MW3.4 km
Roseville Energy Park225 MW5.3 km
Lincoln WWTF Hybrid4 MW5.7 km
Sierra Pacific Lincoln Facility19 MW10.4 km