← Back to map

York Energy Center

York County, Pennsylvania · EIA plant ID 55524 · Operator: Calpine Mid-Merit LLC
Natural gasNatural Gas Fired Combined Cycle⛽ Dual-fuelPJMBA: PJM
Nameplate1,449MWSummer 1,404 MW
Generators7in service
Net generation9,022GWh12 mo to Aug 2026
Capacity factor73%gas/coal/oil units, summer MW
Heat rate7,429Btu/kWhfossil units, electric fuel, HHV
First online2011Runs as baseload

The 12-month figures include preliminary EIA-923 months, which EIA revises. Final data runs through Dec 2025.

Monthly net generation

EIA-923, all units at the plant. Net of station use; storage can go negative.
FinalPreliminary
0200400600800GWh201220132014201520162017201820192020202120222023202420252026

Capacity factor by year

Net MWh ÷ (summer MW × hours), gas/coal/oil units. Each year uses that year's EIA-860 ratings; the hollow dot is the latest 12 months.
0%20%40%60%2012201420162018202020222024202673.4% · 12 mo

Heat rate by year

Electric fuel MMBtu × 1000 ÷ net MWh (Btu/kWh, HHV), fossil units only; CT + CA counted as one combined-cycle block.
7,0007,5008,000201220142016201820202022202420267,429 Btu/kWh · 12 mo
Annual data table
YearNet GWhCapacity factorHeat rate (Btu/kWh)
20111,294.332.3%7,879
20123,483.472.8%7,784
20132,018.742.3%7,892
20142,537.353.1%7,917
20151,976.641.4%7,901
20161,552.432.4%8,028
20171,590.333.3%8,006
20181,838.938.5%7,967
20195,340.649.2%7,192
20208,565.871.0%7,217
20217,64963.6%7,266
20227,125.359.3%7,286
20238,631.470.2%7,352
20249,155.374.2%7,327
20258,785.671.4%7,363

Fuel capability

Gas-fired turbines (CT/GT/CA/CS) that can also burn liquid fuel. EIA-860 Schedule 3 for capability, EIA-923 for actual burn.
StatusLikely still dual fuel
Liquid fuel burned · 36 mo708,750 MMBtu
Last month with liquid burnFeb 2026
Switch while operatingYes
Net summer MW on gas1,329
Net summer MW on oil1,329
Time gas → oilup to 6 h (EIA 6H)
Time oil → gasup to 6 h (EIA 6H)

Generators

EIA-860 (annual) with EIA-860M updates through Sep 2026. EIA-923 reports generation by plant, prime mover and fuel, not by unit, so unit-level output isn't shown.
Gen IDTechnologyPrime moverNameplate MWSummer MWOnlineStatusPlanned retirementOEM / model
CTG1Natural Gas Fired Combined CycleCT120125Mar 2011Operating—coming soon
CTG2Natural Gas Fired Combined CycleCT120125Mar 2011Operating—coming soon
CTG3Natural Gas Fired Combined CycleCT120125Mar 2011Operating—coming soon
CTG5Natural Gas Fired Combined CycleCT234.9214Mar 2019Operating—coming soon
CTG6Natural Gas Fired Combined CycleCT234.9214Mar 2019Operating—coming soon
STG1Natural Gas Fired Combined CycleCA200194Mar 2011Operating—coming soon
STG2Natural Gas Fired Combined CycleCA419.6407Mar 2019Operating—coming soon

Owner / operator

Operator: Calpine Mid-Merit LLC. Ownership shares by in-service nameplate MW (EIA-860 Schedule 4; units not listed there are wholly owned by the operator).
Calpine Mid-Merit LLC100.0%1,449 MW

Nearby plants

Within 80 km.
Peach Bottom2,876 MW4 km
Muddy Run1,072 MW7.8 km
PPL Holtwood247 MW10.2 km
Wildcat Point Generation Facility1,114 MW12.6 km
NAEA Rock Springs LLC796 MW12.7 km
Conowingo531 MW14.4 km