Oroville Cogeneration LP
Butte County, California · EIA plant ID 54477 · Operator: Apex Power Generation Corp.
Nameplate8MWSummer 8 MW
Generators7in service
Net generation0GWh12 mo to Dec 2025
Capacity factor0%gas/coal/oil units, summer MW
Heat rate5,189Btu/kWhfossil units, electric fuel, HHV
First online1990Runs as rarely runs
Monthly net generation
EIA-923, all units at the plant. Net of station use; storage can go negative.
FinalPreliminary
Capacity factor by year
Net MWh ÷ (summer MW × hours), gas/coal/oil units. Each year uses that year's EIA-860 ratings; the hollow dot is the latest 12 months.
Heat rate by year
Electric fuel MMBtu × 1000 ÷ net MWh (Btu/kWh, HHV), fossil units only; CT + CA counted as one combined-cycle block.
Annual data table
| Year | Net GWh | Capacity factor | Heat rate (Btu/kWh) |
|---|---|---|---|
| 2001 | 12.7 | 19.4% | 9,537 |
| 2002 | 10.8 | 16.1% | 13,589 |
| 2003 | 9.1 | 13.6% | 14,410 |
| 2004 | 10.2 | 15.2% | 14,382 |
| 2005 | 8.6 | 13.1% | 14,410 |
| 2006 | 11.2 | 17.1% | 13,738 |
| 2007 | 11.1 | 16.4% | 14,477 |
| 2008 | 11 | 16.3% | 14,193 |
| 2009 | 11.3 | 16.7% | 14,018 |
| 2010 | 10.9 | 16.1% | 13,790 |
| 2011 | 9.7 | 14.4% | 13,392 |
| 2012 | 9.3 | 13.8% | 14,747 |
| 2013 | 0 | 0.0% | — |
| 2014 | 0.2 | 0.4% | 14,847 |
| 2015 | 1.5 | 2.3% | 14,122 |
| 2016 | 0.1 | 0.2% | 5,111 |
| 2017 | 0.4 | 0.6% | 5,092 |
| 2018 | 0.2 | 0.2% | 5,096 |
| 2019 | 0.1 | 0.2% | 5,101 |
| 2020 | 0.1 | 0.2% | 5,079 |
| 2021 | 0.1 | 0.1% | 5,088 |
| 2022 | 0.2 | 0.3% | 5,095 |
| 2023 | 0.2 | 0.4% | 6,328 |
| 2024 | 0.7 | 1.0% | 5,197 |
| 2025 | 0.1 | 0.2% | 5,189 |
Generators
EIA-860 (annual) with EIA-860M updates through Sep 2026. EIA-923 reports generation by plant, prime mover and fuel, not by unit, so unit-level output isn't shown.
| Gen ID | Technology | Prime mover | Nameplate MW | Summer MW | Online | Status | Planned retirement | OEM / model |
|---|---|---|---|---|---|---|---|---|
| GEN1 | Natural Gas Internal Combustion Engine | IC | 1.1 | 1.1 | Jan 1990 | Operating | — | coming soon |
| GEN2 | Natural Gas Internal Combustion Engine | IC | 1.1 | 1.1 | Jan 1990 | Operating | — | coming soon |
| GEN3 | Natural Gas Internal Combustion Engine | IC | 1.1 | 1.1 | Jan 1990 | Operating | — | coming soon |
| GEN4 | Natural Gas Internal Combustion Engine | IC | 1.1 | 1.1 | Jan 1990 | Operating | — | coming soon |
| GEN5 | Natural Gas Internal Combustion Engine | IC | 1.1 | 1.1 | Jan 1990 | Operating | — | coming soon |
| GEN6 | Natural Gas Internal Combustion Engine | IC | 1.1 | 1.1 | Jan 1990 | Operating | — | coming soon |
| GEN7 | Natural Gas Internal Combustion Engine | IC | 1.1 | 1.1 | Jan 1990 | Operating | — | coming soon |
Owner / operator
Operator: Apex Power Generation Corp.. Ownership shares by in-service nameplate MW (EIA-860 Schedule 4; units not listed there are wholly owned by the operator).
| Apex Power Generation Corp. | 100.0% | 8 MW |
Nearby plants
Within 80 km.
| Thermalito Diverson Dam | 3 MW | 4.3 km |
| Thermalito | 115 MW | 6.3 km |
| Kelly Ridge | 10 MW | 7.6 km |
| Edward C Hyatt | 644 MW | 8.3 km |
| Gridley Main Two | 3 MW | 16.7 km |