← Back to map

Archer Daniels Midland Southport

Brunswick County, North Carolina · EIA plant ID 54316 · Operator: Archer Daniels Midland Co
Natural gasNatural Gas Fired Combustion Turbine⛽ Dual-fuelBA: CPLE
Nameplate53MWSummer 45 MW
Generators3in service
Net generation0GWh12 mo to Dec 2025
Capacity factor0%gas/coal/oil units, summer MW
Heat rate—Btu/kWhfossil units, electric fuel, HHV
First online1992Runs as rarely runs

Monthly net generation

EIA-923, all units at the plant. Net of station use; storage can go negative.
FinalPreliminary
02.557.510GWh2001200320052007200920112013201520172019202120232025

Capacity factor by year

Net MWh ÷ (summer MW × hours), gas/coal/oil units. Each year uses that year's EIA-860 ratings; the hollow dot is the latest 12 months.
0%1%2%3%200520102015202020250.0% · 12 mo

Heat rate by year

Electric fuel MMBtu × 1000 ÷ net MWh (Btu/kWh, HHV), fossil units only; CT + CA counted as one combined-cycle block.
7,50010,00012,50015,0002005201020152020
Annual data table
YearNet GWhCapacity factorHeat rate (Btu/kWh)
200118.8——
20021.8——
20031.30.3%13,892
20044.51.1%9,064
20059.22.3%9,064
20062.70.7%9,064
20076.61.7%11,373
20081.80.4%8,882
20091.60.4%8,883
201010.92.8%8,883
20115.21.3%8,883
201220.5%8,883
20130.50.1%8,879
20140.80.2%8,883
20152.70.7%8,882
20161.30.3%—
20170.50.1%—
20182.70.7%14,960
201900.0%—
202000.0%—
202100.0%—
20221.30.3%15,584
202300.0%—
202400.0%—
202500.0%—

Fuel capability

Gas-fired turbines (CT/GT/CA/CS) that can also burn liquid fuel. EIA-860 Schedule 3 for capability, EIA-923 for actual burn.
StatusLikely still dual fuel
Liquid fuel burned · 36 mo8,392 MMBtu
Last month with liquid burnDec 2023
Switch while operatingYes
Net summer MW on gas36
Net summer MW on oil36
Time gas → oilup to 1 h (EIA 1H)
Time oil → gasup to 1 h (EIA 1H)

Generators

EIA-860 (annual) with EIA-860M updates through Sep 2026. EIA-923 reports generation by plant, prime mover and fuel, not by unit, so unit-level output isn't shown.
Gen IDTechnologyPrime moverNameplate MWSummer MWOnlineStatusPlanned retirementOEM / model
GEN1Natural Gas Fired Combustion TurbineGT1815Sep 1992Operating (Standby / backup)—coming soon
GEN2Natural Gas Fired Combustion TurbineGT17.515Oct 1992Operating (Standby / backup)—coming soon
GEN3Natural Gas Fired Combustion TurbineGT1715Apr 1995Operating (Standby / backup)—coming soon

Owner / operator

Operator: Archer Daniels Midland Co. Ownership shares by in-service nameplate MW (EIA-860 Schedule 4; units not listed there are wholly owned by the operator).
Archer Daniels Midland Co100.0%53 MW

Nearby plants

Within 80 km.
CPI USA NC Southportretired2 km
Brunswick Nuclear2,003 MW2.9 km
Zion Hill BESS5 MW22.4 km
AGA TAG Solar IV LLC5 MW37.7 km
ATOOD Solar IV, LLC5 MW37.9 km
L V Sutton Combined Cycle851 MW38.2 km