← Back to map

Lauderdale

Broward County, Florida · EIA plant ID 613 · Operator: Florida Power & Light Co
Natural gasNatural Gas Fired Combustion Turbine⛽ Dual-fuelBA: FPL
Nameplate1,216MWSummer 1,224 MW
Generators7in service
Net generation258GWh12 mo to Aug 2026
Capacity factor2%gas/coal/oil units, summer MW
Heat rate11,247Btu/kWhfossil units, electric fuel, HHV
First online1970Runs as peaking

The 12-month figures include preliminary EIA-923 months, which EIA revises. Final data runs through Dec 2025.

Monthly net generation

EIA-923, all units at the plant. Net of station use; storage can go negative.
FinalPreliminary
0200400600GWh2001200320052007200920112013201520172019202120232025

Capacity factor by year

Net MWh ÷ (summer MW × hours), gas/coal/oil units. Each year uses that year's EIA-860 ratings; the hollow dot is the latest 12 months.
0%20%40%200520102015202020252.3% · 12 mo

Heat rate by year

Electric fuel MMBtu × 1000 ÷ net MWh (Btu/kWh, HHV), fossil units only; CT + CA counted as one combined-cycle block.
6,0008,00010,0002005201020152020202511,247 Btu/kWh · 12 mo
Annual data table
YearNet GWhCapacity factorHeat rate (Btu/kWh)
20016,164.2——
20026,471.1——
20035,971.440.1%8,059
20045,165.834.6%8,154
20055,423.136.4%8,041
20065,898.239.6%8,198
20074,962.233.1%8,302
20085,068.433.7%8,314
20095,07733.9%8,294
20104,472.129.6%8,425
20115,094.333.7%8,351
20124,406.829.1%8,355
20134,764.431.6%8,351
20144,559.530.2%8,667
20154,52029.9%8,684
20163,058.919.8%8,756
20173,317.418.0%8,684
20182,910.616.4%8,700
2019421.93.9%10,578
2020373.73.5%10,667
2021362.83.4%10,623
2022314.92.9%11,385
2023285.52.7%11,125
2024244.52.3%10,781
2025262.92.5%10,895

Fuel capability

Gas-fired turbines (CT/GT/CA/CS) that can also burn liquid fuel. EIA-860 Schedule 3 for capability, EIA-923 for actual burn.
StatusLikely still dual fuel
Liquid fuel burned · 36 mo154,759 MMBtu
Last month with liquid burnMay 2026
Switch while operatingYes
Net summer MW on gas1,224
Net summer MW on oil1,224
Time gas → oilup to 1 h (EIA 1H)
Time oil → gasup to 1 h (EIA 1H)

Generators

EIA-860 (annual) with EIA-860M updates through Sep 2026. EIA-923 reports generation by plant, prime mover and fuel, not by unit, so unit-level output isn't shown.
Gen IDTechnologyPrime moverNameplate MWSummer MWOnlineStatusPlanned retirementOEM / model
3Natural Gas Fired Combustion TurbineGT34.234.3Aug 1970Operating—coming soon
5Natural Gas Fired Combustion TurbineGT34.234.3Aug 1970Operating—coming soon
6ANatural Gas Fired Combustion TurbineGT229.5231Dec 2016Operating—coming soon
6BNatural Gas Fired Combustion TurbineGT229.5231Dec 2016Operating—coming soon
6CNatural Gas Fired Combustion TurbineGT229.5231Dec 2016Operating—coming soon
6DNatural Gas Fired Combustion TurbineGT229.5231Dec 2016Operating—coming soon
6ENatural Gas Fired Combustion TurbineGT229.5231Dec 2016Operating—coming soon
7GT1Natural Gas Fired Combined CycleCT385.6385.6planned May 2022not_current—coming soon
7GT2Natural Gas Fired Combined CycleCT385.6385.6planned May 2022not_current—coming soon
GT4Natural Gas Fired Combustion TurbineGT34.235Aug 1970not_current—coming soon
GT5Natural Gas Fired Combustion TurbineGT34.235Aug 1970not_current—coming soon
ST7Natural Gas Fired Combined CycleCA391.8391.8planned May 2022not_current—coming soon
1Natural Gas Fired Combustion TurbineGT34.235Aug 1970Retired Dec 2016—coming soon
10Natural Gas Fired Combustion TurbineGT34.235Aug 1970Retired Dec 2016—coming soon
11Natural Gas Fired Combustion TurbineGT34.235Aug 1970Retired Dec 2016—coming soon
12Natural Gas Fired Combustion TurbineGT34.235Aug 1970Retired Dec 2016—coming soon
13Natural Gas Fired Combustion TurbineGT34.235Aug 1972Retired Dec 2016—coming soon
14Natural Gas Fired Combustion TurbineGT34.235Aug 1972Retired Dec 2016—coming soon
15Natural Gas Fired Combustion TurbineGT34.235Aug 1972Retired Dec 2016—coming soon
16Natural Gas Fired Combustion TurbineGT34.235Aug 1972Retired Dec 2016—coming soon
17Natural Gas Fired Combustion TurbineGT34.235Aug 1972Retired Dec 2016—coming soon
18Natural Gas Fired Combustion TurbineGT34.235Aug 1972Retired Dec 2016—coming soon
19Natural Gas Fired Combustion TurbineGT34.235Aug 1972Retired Dec 2016—coming soon
2Natural Gas Fired Combustion TurbineGT34.235Aug 1970Retired Dec 2016—coming soon
20Natural Gas Fired Combustion TurbineGT34.235Aug 1972Retired Dec 2016—coming soon
21Natural Gas Fired Combustion TurbineGT34.235Aug 1972Retired Dec 2016—coming soon
22Natural Gas Fired Combustion TurbineGT34.235Aug 1972Retired Dec 2016—coming soon
23Natural Gas Fired Combustion TurbineGT34.235Aug 1972Retired Dec 2016—coming soon
24Natural Gas Fired Combustion TurbineGT34.235Aug 1972Retired Dec 2016—coming soon
4Natural Gas Fired Combustion TurbineGT34.235Aug 1970Retired Dec 2016—coming soon
4GT1Natural Gas Fired Combined CycleCT185—May 1993Retired Dec 2018—coming soon
4GT2Natural Gas Fired Combined CycleCT185—May 1993Retired Dec 2018—coming soon
5GT1Natural Gas Fired Combined CycleCT185—Jun 1993Retired Dec 2018—coming soon
5GT2Natural Gas Fired Combined CycleCT185—Jun 1993Retired Dec 2018—coming soon
6Natural Gas Fired Combustion TurbineGT34.235Aug 1970Retired Dec 2016—coming soon
7Natural Gas Fired Combustion TurbineGT34.235Aug 1970Retired Dec 2016—coming soon
8Natural Gas Fired Combustion TurbineGT34.235Aug 1970Retired Dec 2016—coming soon
9Natural Gas Fired Combustion TurbineGT34.235Aug 1970Retired Dec 2016—coming soon
ST4Natural Gas Fired Combined CycleCA151.2442Oct 1957Retired Dec 2018—coming soon
ST5Natural Gas Fired Combined CycleCA151.2442Apr 1958Retired Dec 2018—coming soon

Owner / operator

Operator: Florida Power & Light Co. Ownership shares by in-service nameplate MW (EIA-860 Schedule 4; units not listed there are wholly owned by the operator).
Florida Power & Light Co100.0%1,216 MW

Nearby plants

Within 80 km.
Dania Beach 71,448 MW0 km
Wheelabrator South Broward66 MW0 km
Port Everglades1,352 MW7.5 km
Pembroke Lakes Mall1 MW12.4 km
CSL Gas Recovery11 MW24.6 km
Wynwood Energy Storage10 MW30 km