← Back to map

Tenaska Virginia Generating Station

Fluvanna County, Virginia · EIA plant ID 55439 · Operator: Tenaska Virginia Partners LP
Natural gasNatural Gas Fired Combined Cycle⛽ Dual-fuelPJMBA: PJM
Nameplate1,011MWSummer 937 MW
Generators4in service
Net generation4,294GWh12 mo to Aug 2026
Capacity factor52%gas/coal/oil units, summer MW
Heat rate7,086Btu/kWhfossil units, electric fuel, HHV
First online2004Runs as baseload

The 12-month figures include preliminary EIA-923 months, which EIA revises. Final data runs through Dec 2025.

Monthly net generation

EIA-923, all units at the plant. Net of station use; storage can go negative.
FinalPreliminary
0200400600GWh20052007200920112013201520172019202120232025

Capacity factor by year

Net MWh ÷ (summer MW × hours), gas/coal/oil units. Each year uses that year's EIA-860 ratings; the hollow dot is the latest 12 months.
0%25%50%75%2005201020152020202552.3% · 12 mo

Heat rate by year

Electric fuel MMBtu × 1000 ÷ net MWh (Btu/kWh, HHV), fossil units only; CT + CA counted as one combined-cycle block.
7,0007,2007,400200520102015202020257,086 Btu/kWh · 12 mo
Annual data table
YearNet GWhCapacity factorHeat rate (Btu/kWh)
2004317.15.9%7,383
20051,113.414.0%7,496
20061,169.414.8%7,394
20072,051.325.0%7,425
20081,494.618.2%7,407
20092,065.925.2%7,352
20103,579.644.1%7,284
20114,332.553.8%7,515
20125,349.265.8%7,239
20134,482.656.9%7,255
20143,701.947.0%7,389
20155,000.563.5%7,390
20165,207.262.8%7,195
20176,038.573.1%7,098
20185,771.870.6%7,159
20195,93872.5%7,145
20204,533.255.5%7,248
20213,648.744.7%7,215
20223,725.445.7%7,285
20233,93348.3%7,207
20245,122.662.2%7,229
20255,136.862.5%7,208

Fuel capability

Gas-fired turbines (CT/GT/CA/CS) that can also burn liquid fuel. EIA-860 Schedule 3 for capability, EIA-923 for actual burn.
StatusLikely still dual fuel
Liquid fuel burned · 36 mo121,347 MMBtu
Last month with liquid burnFeb 2026
Switch while operating—
Net summer MW on gas—
Net summer MW on oil—
Time gas → oil—
Time oil → gas—

Generators

EIA-860 (annual) with EIA-860M updates through Sep 2026. EIA-923 reports generation by plant, prime mover and fuel, not by unit, so unit-level output isn't shown.
Gen IDTechnologyPrime moverNameplate MWSummer MWOnlineStatusPlanned retirementOEM / model
CTG1Natural Gas Fired Combined CycleCT207173.4Apr 2004Operating—coming soon
CTG2Natural Gas Fired Combined CycleCT207174.4Apr 2004Operating—coming soon
CTG3Natural Gas Fired Combined CycleCT207183.5Apr 2004Operating—coming soon
STG1Natural Gas Fired Combined CycleCA390.4406.1Apr 2004Operating—coming soon

Owner / operator

Operator: Tenaska Virginia Partners LP. Ownership shares by in-service nameplate MW (EIA-860 Schedule 4; units not listed there are wholly owned by the operator).
Tenaska Virginia I LP99.0%1,001 MW
Tenaska Virginia Inc0.3%3 MW
Tenaska TVP General, LLC0.3%3 MW
TC Virginia GP LLC0.3%3 MW
Tyr TVP GP, LLC0.1%1 MW

Nearby plants

Within 80 km.
Cunningham Solar LLC5 MW5.7 km
Rivanna Solar13 MW11.2 km
Riverstone Solar—16.6 km
Palmer Solar Center5 MW17.3 km
Bear Garden559 MW20.8 km
Martin Solar Center5 MW29.2 km