← Back to map

International Paper Riverdale Mill

Dallas County, Alabama · EIA plant ID 54096 · Operator: International Paper Co-Riverdl
Natural gasNatural Gas Fired Combined CycleNatural Gas Steam TurbineWood/Wood Waste BiomassBA: SOCO
Nameplate104MWSummer 104 MW
Generators4in service
Net generation552GWh12 mo to Dec 2025
Capacity factor78%gas/coal/oil units, summer MW
Heat rate—Btu/kWhfossil units, electric fuel, HHV
First online1967Runs as baseload

Monthly net generation

EIA-923, all units at the plant. Net of station use; storage can go negative.
FinalPreliminary
0204060GWh2001200320052007200920112013201520172019202120232025

Capacity factor by year

Net MWh ÷ (summer MW × hours), gas/coal/oil units. Each year uses that year's EIA-860 ratings; the hollow dot is the latest 12 months.
0%25%50%75%2005201020152020202578.4% · 12 mo

Heat rate by year

Electric fuel MMBtu × 1000 ÷ net MWh (Btu/kWh, HHV), fossil units only; CT + CA counted as one combined-cycle block.
2,5005,0007,50010,00020052010201520202025
Annual data table
YearNet GWhCapacity factorHeat rate (Btu/kWh)
2001679——
2002651.9——
2003509.831.9%10,818
200456942.9%5,953
2005469.429.6%5,885
2006372.215.4%5,385
200736713.9%4,516
2008363.316.0%5,276
2009322.711.7%—
2010445.831.1%5,890
2011551.540.9%5,727
2012612.451.8%5,719
2013568.150.6%5,712
2014550.433.9%5,220
2015553.466.6%5,678
201657771.2%5,282
2017587.176.3%5,249
2018605.277.3%5,249
2019601.779.2%5,135
2020353.447.3%—
202162081.3%—
2022400.145.5%4,709
2023462.763.6%4,126
2024562.277.0%4,008
2025552.278.3%—

Fuel capability

Gas-fired turbines (CT/GT/CA/CS) that can also burn liquid fuel. EIA-860 Schedule 3 for capability, EIA-923 for actual burn.
StatusListed in EIA-860, no liquid burn in 36 months
Liquid fuel burned · 36 mo0 MMBtu
Last month with liquid burn—
Switch while operating—
Net summer MW on gas—
Net summer MW on oil—
Time gas → oil—
Time oil → gas—

Generators

EIA-860 (annual) with EIA-860M updates through Sep 2026. EIA-923 reports generation by plant, prime mover and fuel, not by unit, so unit-level output isn't shown.
Gen IDTechnologyPrime moverNameplate MWSummer MWOnlineStatusPlanned retirementOEM / model
GEN1Natural Gas Steam TurbineST11.611.6Jan 1967Operating—coming soon
GEN2Wood/Wood Waste BiomassST37.437.4Jan 1985Operating—coming soon
GEN3Natural Gas Fired Combined CycleCA1717Nov 1994Operating—coming soon
GEN4Natural Gas Fired Combined CycleCT38.238.2Nov 1994Operating (Standby / backup)—coming soon

Owner / operator

Operator: International Paper Co-Riverdl. Ownership shares by in-service nameplate MW (EIA-860 Schedule 4; units not listed there are wholly owned by the operator).
International Paper Co-Riverdl100.0%104 MW

Nearby plants

Within 80 km.
Jones Bluff82 MW13.9 km
Tenaska Central Alabama Generating Stn927 MW27.7 km
Tenaska Lindsay Hill Generating Station939 MW28 km
E B Harris Electric Generating Plant1,304 MW28.3 km
General Electric Plastic97 MW34.9 km
Alabama Creek Solar—35.3 km