Hal C Weaver Power Plant

Travis County, Texas · EIA plant ID 50118 · Operator: University of Texas at Austin
Natural gasNatural Gas Fired Combined CycleERCOTBA: ERCO
Nameplate152MWSummer 147 MW
Generators6in service
Net generation357GWh12 mo to Dec 2025
Capacity factor28%gas/coal/oil units, summer MW
Heat rate4,188Btu/kWhfossil units, electric fuel, HHV
First online1951Runs as intermediate

Monthly net generation

EIA-923, all units at the plant. Net of station use; storage can go negative.
FinalPreliminary
0102030GWh2001200320052007200920112013201520172019202120232025

Capacity factor by year

Net MWh ÷ (summer MW × hours), gas/coal/oil units. Each year uses that year's EIA-860 ratings; the hollow dot is the latest 12 months.
0%20%40%2005201020152020202527.8% · 12 mo

Heat rate by year

Electric fuel MMBtu × 1000 ÷ net MWh (Btu/kWh, HHV), fossil units only; CT + CA counted as one combined-cycle block.
2,0004,0006,0008,00010,000200520102015202020254,188 Btu/kWh · 12 mo
Annual data table
YearNet GWhCapacity factorHeat rate (Btu/kWh)
2001304.4——
2002302——
2003311.243.8%10,457
2004324.343.6%7,121
2005332.737.0%7,121
2006341.938.0%7,121
2007337.230.5%7,121
2008342.233.6%7,207
2009353.835.5%7,164
2010366.929.6%7,237
201134226.6%7,154
2012338.426.2%7,203
2013330.925.7%7,185
2014324.625.3%7,128
2015322.625.1%7,132
2016338.526.3%4,196
2017333.525.9%4,294
2018336.326.2%4,188
2019332.225.8%4,188
202029923.2%4,188
202132725.4%4,188
2022344.826.8%4,188
2023354.427.6%4,188
2024361.228.0%4,188
2025357.427.8%4,188

Fuel capability

Gas-fired turbines (CT/GT/CA/CS) that can also burn liquid fuel. EIA-860 Schedule 3 for capability, EIA-923 for actual burn.
StatusListed in EIA-860, no liquid burn in 36 months
Liquid fuel burned · 36 mo0 MMBtu
Last month with liquid burn—
Switch while operatingYes
Net summer MW on gas67
Net summer MW on oil67
Time gas → oilup to 6 h (EIA 6H)
Time oil → gasup to 6 h (EIA 6H)

Generators

EIA-860 (annual) with EIA-860M updates through Sep 2026. EIA-923 reports generation by plant, prime mover and fuel, not by unit, so unit-level output isn't shown.
Gen IDTechnologyPrime moverNameplate MWSummer MWOnlineStatusPlanned retirementOEM / model
GEN10Natural Gas Fired Combined CycleCT34.433Mar 2010Operating (Out of service, expected back within the year)—coming soon
GEN4Natural Gas Fired Combined CycleCA7.67.6Oct 1951Operating · retirement planned (Out of service)Jan 2028coming soon
GEN5Natural Gas Fired Combined CycleCA66Sep 1959Operating · retirement planned (Standby / backup)Jan 2028coming soon
GEN7Natural Gas Fired Combined CycleCA28.827.6Jan 1979Operating—coming soon
GEN8Natural Gas Fired Combined CycleCT48.546.5Nov 1987Operating—coming soon
GEN9Natural Gas Fired Combined CycleCA27.226.1Nov 2004Operating—coming soon
GEN1Natural Gas Steam TurbineST1.51.4Oct 1933Retired Dec 2001—coming soon
GEN2Natural Gas Steam TurbineST1.51.4Oct 1933Retired Dec 2001—coming soon
GEN3Natural Gas Steam TurbineST2.52.3Jan 1938Retired Dec 2001—coming soon
GEN6Natural Gas Fired Combined CycleCT12.512.5Jan 1968Retired Mar 2008—coming soon

Owner / operator

Operator: University of Texas at Austin. Ownership shares by in-service nameplate MW (EIA-860 Schedule 4; units not listed there are wholly owned by the operator).
University of Texas at Austin100.0%153 MW

Nearby plants

Within 80 km.
Robert Mueller Energy Center6 MW3.4 km
Austin18 MW4.7 km
Kingsberry Energy Storage System2 MW5.3 km
PowerFin Kingsbery3 MW5.4 km
System Control Center5 MW7.9 km
ABIA Parking Structure2 MW11.2 km