Miami Fort
Hamilton County, Ohio · EIA plant ID 2832 · Operator: Dynegy Miami Fort
Nameplate1,181MWSummer 1,076 MW
Generators6in service
Net generation6,707GWh12 mo to Aug 2026
Capacity factor71%gas/coal/oil units, summer MW
Heat rate10,658Btu/kWhfossil units, electric fuel, HHV
First online1971Runs as baseload
The 12-month figures include preliminary EIA-923 months, which EIA revises. Final data runs through Dec 2025.
Monthly net generation
EIA-923, all units at the plant. Net of station use; storage can go negative.
FinalPreliminary
Capacity factor by year
Net MWh ÷ (summer MW × hours), gas/coal/oil units. Each year uses that year's EIA-860 ratings; the hollow dot is the latest 12 months.
Heat rate by year
Electric fuel MMBtu × 1000 ÷ net MWh (Btu/kWh, HHV), fossil units only; CT + CA counted as one combined-cycle block.
Annual data table
| Year | Net GWh | Capacity factor | Heat rate (Btu/kWh) |
|---|---|---|---|
| 2001 | 6,799.9 | — | — |
| 2002 | 7,587.2 | — | — |
| 2003 | 7,618.2 | 66.9% | 10,228 |
| 2004 | 7,614.5 | 66.7% | 10,266 |
| 2005 | 7,566.9 | 66.5% | 10,240 |
| 2006 | 7,678.9 | 67.4% | 10,178 |
| 2007 | 6,920.5 | 60.8% | 10,289 |
| 2008 | 7,441.2 | 69.5% | 10,297 |
| 2009 | 8,634.6 | 79.6% | 10,069 |
| 2010 | 8,562.7 | 78.8% | 10,145 |
| 2011 | 7,441.9 | 68.5% | 10,302 |
| 2012 | 8,307.8 | 76.3% | 10,228 |
| 2013 | 8,846.6 | 81.5% | 10,283 |
| 2014 | 7,676.7 | 70.7% | 10,383 |
| 2015 | 6,605.1 | 65.9% | 10,347 |
| 2016 | 6,764.7 | 71.6% | 10,339 |
| 2017 | 6,744.2 | 71.5% | 10,304 |
| 2018 | 5,409.4 | 57.4% | 10,553 |
| 2019 | 6,974.5 | 74.0% | 10,272 |
| 2020 | 6,687.3 | 70.8% | 10,390 |
| 2021 | 6,776.5 | 71.9% | 10,328 |
| 2022 | 6,241.2 | 66.2% | 10,632 |
| 2023 | 2,781.6 | 29.5% | 11,038 |
| 2024 | 5,520.9 | 58.4% | 10,716 |
| 2025 | 6,716.2 | 71.3% | 10,530 |
Generators
EIA-860 (annual) with EIA-860M updates through Sep 2026. EIA-923 reports generation by plant, prime mover and fuel, not by unit, so unit-level output isn't shown.
| Gen ID | Technology | Prime mover | Nameplate MW | Summer MW | Online | Status | Planned retirement | OEM / model |
|---|---|---|---|---|---|---|---|---|
| 7 | Conventional Steam Coal | ST | 557.1 | 510 | May 1975 | Operating | — | coming soon |
| 8 | Conventional Steam Coal | ST | 557.7 | 510 | Feb 1978 | Operating | — | coming soon |
| GT3 | Petroleum Liquids | GT | 16.5 | 14 | Jul 1971 | Operating | — | coming soon |
| GT4 | Petroleum Liquids | GT | 16.5 | 14 | Aug 1971 | Operating | — | coming soon |
| GT5 | Petroleum Liquids | GT | 16.5 | 14 | Sep 1971 | Operating | — | coming soon |
| GT6 | Petroleum Liquids | GT | 16.5 | 14 | Oct 1971 | Operating | — | coming soon |
| 5 | Conventional Steam Coal | ST | 100 | 80 | Dec 1949 | Retired Jan 2008 | — | coming soon |
| 6 | Conventional Steam Coal | ST | 163.2 | 163 | Nov 1960 | Retired Jun 2015 | — | coming soon |
Owner / operator
Operator: Dynegy Miami Fort. Ownership shares by in-service nameplate MW (EIA-860 Schedule 4; units not listed there are wholly owned by the operator).
| Dynegy Miami Fort | 100.0% | 1,181 MW |
Nearby plants
Within 80 km.
| Lawrenceburg Power, LLC | 1,232 MW | 6 km |
| Aero Solar Facility | 2 MW | 15.4 km |
| RA Jones Roof Mounted Solar System | 1 MW | 20.4 km |
| L'Oreal Solar - Florence | 1 MW | 21.9 km |
| Willey Battery Utility | retired | 22.2 km |
| East Bend | 772 MW | 23.6 km |