← Back to map

Hillburn

Rockland County, New York · EIA plant ID 2628 · Operator: Alliance NYGT, LLC
Natural gasNatural Gas Fired Combustion Turbine⛽ Dual-fuelNYISOBA: NYIS
Nameplate47MWSummer 33 MW
Generators1in service
Net generation1GWh12 mo to Dec 2025
Capacity factor0%gas/coal/oil units, summer MW
Heat rate17,114Btu/kWhfossil units, electric fuel, HHV
First online1972Runs as rarely runs

Monthly net generation

EIA-923, all units at the plant. Net of station use; storage can go negative.
FinalPreliminary
-0.500.511.5GWh2001200320052007200920112013201520172019202120232025

Capacity factor by year

Net MWh ÷ (summer MW × hours), gas/coal/oil units. Each year uses that year's EIA-860 ratings; the hollow dot is the latest 12 months.
0%1%1%200520102015202020250.2% · 12 mo

Heat rate by year

Electric fuel MMBtu × 1000 ÷ net MWh (Btu/kWh, HHV), fossil units only; CT + CA counted as one combined-cycle block.
010,00020,0002005201020152020202517,114 Btu/kWh · 12 mo
Annual data table
YearNet GWhCapacity factorHeat rate (Btu/kWh)
200120.6%18,922
200220.6%19,184
20033.91.2%15,765
200400.0%—
20050.70.2%23,894
20060.40.1%—
20070.60.2%14,464
20080.20.1%19,161
20090.10.0%8,517
20100.20.1%24,131
20110.10.0%25,675
20120.30.1%17,036
20130.20.1%18,495
20140.30.1%16,903
20150.10.1%17,765
20160.30.1%20,223
20170.40.1%18,979
20180.30.1%15,434
20190.30.1%15,351
20200.20.1%16,554
20210.10.1%23,609
20221.40.5%16,664
20230.70.2%18,159
20240.50.2%18,858
20250.70.2%17,114

Fuel capability

Gas-fired turbines (CT/GT/CA/CS) that can also burn liquid fuel. EIA-860 Schedule 3 for capability, EIA-923 for actual burn.
StatusLikely still dual fuel
Liquid fuel burned · 36 mo6 MMBtu
Last month with liquid burnFeb 2023
Switch while operatingNo
Net summer MW on gas33
Net summer MW on oil33
Time gas → oilup to 1 h (EIA 1H)
Time oil → gasup to 1 h (EIA 1H)

Generators

EIA-860 (annual) with EIA-860M updates through Sep 2026. EIA-923 reports generation by plant, prime mover and fuel, not by unit, so unit-level output isn't shown.
Gen IDTechnologyPrime moverNameplate MWSummer MWOnlineStatusPlanned retirementOEM / model
GEN1Natural Gas Fired Combustion TurbineGT46.533.1Jul 1972Operating—coming soon

Owner / operator

Operator: Alliance NYGT, LLC. Ownership shares by in-service nameplate MW (EIA-860 Schedule 4; units not listed there are wholly owned by the operator).
Alliance NYGT, LLC100.0%47 MW

Nearby plants

Within 80 km.
Good Samaritan Hospital2 MW3 km
Ramapo4 MW5.2 km
Bergenmand Solar Partners, LLC Mahwah1 MW5.5 km
NY3 Battery3 MW10 km
Rockland Bakery Inc.2 MW11 km
Lederle Laboratories23 MW13.5 km