← Back to map

Encogen

Whatcom County, Washington · EIA plant ID 7870 · Operator: Puget Sound Energy Inc
Natural gasNatural Gas Fired Combined Cycle⛽ Dual-fuelBA: PSEI
Nameplate176MWSummer 159 MW
Generators4in service
Net generation157GWh12 mo to Aug 2026
Capacity factor11%gas/coal/oil units, summer MW
Heat rate9,526Btu/kWhfossil units, electric fuel, HHV
First online1993Runs as baseload

The 12-month figures include preliminary EIA-923 months, which EIA revises. Final data runs through Dec 2025.

Monthly net generation

EIA-923, all units at the plant. Net of station use; storage can go negative.
FinalPreliminary
-50050100GWh2001200320052007200920112013201520172019202120232025

Capacity factor by year

Net MWh ÷ (summer MW × hours), gas/coal/oil units. Each year uses that year's EIA-860 ratings; the hollow dot is the latest 12 months.
0%20%40%60%2005201020152020202511.2% · 12 mo

Heat rate by year

Electric fuel MMBtu × 1000 ÷ net MWh (Btu/kWh, HHV), fossil units only; CT + CA counted as one combined-cycle block.
8,00010,00012,000200520102015202020259,526 Btu/kWh · 12 mo
Annual data table
YearNet GWhCapacity factorHeat rate (Btu/kWh)
20011,402.7——
2002941.6——
2003748.753.4%9,223
2004456.330.6%9,563
2005459.130.8%9,298
200626017.5%9,848
2007143.19.6%11,096
200898.98.1%10,250
2009380.131.2%8,907
2010146.210.5%12,435
201191.86.6%9,401
2012112.48.0%9,236
2013283.520.3%9,121
2014219.615.7%9,297
2015300.321.5%9,212
2016212.715.2%8,903
2017202.514.5%9,381
2018200.514.4%9,299
2019401.328.7%9,232
2020370.126.4%9,316
2021530.538.0%9,388
2022426.830.6%9,278
202390364.7%9,141
202475453.8%9,337
2025354.125.4%9,361

Fuel capability

Gas-fired turbines (CT/GT/CA/CS) that can also burn liquid fuel. EIA-860 Schedule 3 for capability, EIA-923 for actual burn.
StatusLikely still dual fuel
Liquid fuel burned · 36 mo16,502 MMBtu
Last month with liquid burnAug 2026
Switch while operatingYes
Net summer MW on gas104
Net summer MW on oil102
Time gas → oilup to 1 h (EIA 1H)
Time oil → gasup to 1 h (EIA 1H)

Generators

EIA-860 (annual) with EIA-860M updates through Sep 2026. EIA-923 reports generation by plant, prime mover and fuel, not by unit, so unit-level output isn't shown.
Gen IDTechnologyPrime moverNameplate MWSummer MWOnlineStatusPlanned retirementOEM / model
CTG1Natural Gas Fired Combined CycleCT39.434.5Mar 1993Operating—coming soon
CTG2Natural Gas Fired Combined CycleCT39.434.5Mar 1993Operating—coming soon
CTG3Natural Gas Fired Combined CycleCT39.434.5Mar 1993Operating—coming soon
STGNatural Gas Fired Combined CycleCA58.255.9Apr 1993Operating—coming soon

Owner / operator

Operator: Puget Sound Energy Inc. Ownership shares by in-service nameplate MW (EIA-860 Schedule 4; units not listed there are wholly owned by the operator).
Puget Sound Energy Inc100.0%176 MW

Nearby plants

Within 80 km.
Ferndale Generating Station286 MW17.3 km
March Point Cogeneration140 MW31.1 km
Sumas Power Plant126 MW31.3 km
Fredonia376 MW32.5 km
Sierra Pacific Burlington Facility28 MW33.4 km
Glacier Battery Storage2 MW42.6 km