← Back to map

Angus AnsonRetirement planned

Minnehaha County, South Dakota · EIA plant ID 7237 · Operator: Northern States Power Co - Minnesota
Natural gasNatural Gas Fired Combustion Turbine⛽ Dual-fuelMISOBA: MISO
Nameplate406MWSummer 343 MW
Generators3in service
Net generation239GWh12 mo to Dec 2025
Capacity factor8%gas/coal/oil units, summer MW
Heat rate12,187Btu/kWhfossil units, electric fuel, HHV
First online1994Runs as peaking

Monthly net generation

EIA-923, all units at the plant. Net of station use; storage can go negative.
FinalPreliminary
-20020406080GWh2001200320052007200920112013201520172019202120232025

Capacity factor by year

Net MWh ÷ (summer MW × hours), gas/coal/oil units. Each year uses that year's EIA-860 ratings; the hollow dot is the latest 12 months.
0%5%10%200520102015202020257.9% · 12 mo

Heat rate by year

Electric fuel MMBtu × 1000 ÷ net MWh (Btu/kWh, HHV), fossil units only; CT + CA counted as one combined-cycle block.
10,00012,00014,00016,0002005201020152020202512,187 Btu/kWh · 12 mo
Annual data table
YearNet GWhCapacity factorHeat rate (Btu/kWh)
2001126.96.3%13,969
200269.93.5%14,046
2003100.15.3%13,790
2004105.75.6%14,189
20052659.5%13,190
2006208.16.2%13,122
2007278.18.3%13,028
2008121.43.6%12,824
200915.10.4%16,490
201084.92.9%12,700
201153.81.8%13,283
2012112.73.9%12,868
201340.11.4%13,493
201425.80.9%14,344
20151033.6%12,129
201665.72.3%12,470
201770.12.5%12,101
2018120.34.2%11,912
20191093.8%11,841
2020133.44.6%11,808
2021159.15.6%11,873
2022114.94.0%12,065
2023232.38.1%11,616
2024237.37.9%12,252
2025238.57.9%12,187

Fuel capability

Gas-fired turbines (CT/GT/CA/CS) that can also burn liquid fuel. EIA-860 Schedule 3 for capability, EIA-923 for actual burn.
StatusLikely still dual fuel
Liquid fuel burned · 36 mo90,539 MMBtu
Last month with liquid burnDec 2025
Switch while operatingYes
Net summer MW on gas180
Net summer MW on oil180
Time gas → oilup to 1 h (EIA 1H)
Time oil → gasup to 6 h (EIA 6H)

Generators

EIA-860 (annual) with EIA-860M updates through Sep 2026. EIA-923 reports generation by plant, prime mover and fuel, not by unit, so unit-level output isn't shown.
Gen IDTechnologyPrime moverNameplate MWSummer MWOnlineStatusPlanned retirementOEM / model
1Natural Gas Fired Combustion TurbineGT119.797Aug 1994Operating · retirement plannedDec 2040coming soon
2Natural Gas Fired Combustion TurbineGT119.799Aug 1994Operating · retirement plannedDec 2040coming soon
4Natural Gas Fired Combustion TurbineGT166.3147Jun 2005Operating · retirement plannedDec 2029coming soon

Owner / operator

Operator: Northern States Power Co - Minnesota. Ownership shares by in-service nameplate MW (EIA-860 Schedule 4; units not listed there are wholly owned by the operator).
Northern States Power Co - Minnesota100.0%406 MW

Nearby plants

Within 80 km.
Minwind 3-9retired20 km
Walleye Wind110 MW20.1 km
Minwind4 MW27.2 km
Rock County Wind Fuel, LLC5 MW30.3 km
Luverne10 MW35.4 km
Prairie Rose Wind Farm200 MW35.5 km