Bristol PlantRetired
Bristol City County, Virginia · EIA plant ID 60222 · Operator: Ingenco Renewable Development, LLC
×4 MW other retired since 2020 (latest Jun 2024)
Nameplate—MWSummer — MW
Generators0in service
Net generation—GWh12 mo
Capacity factor—no 923 generation in the last 12 months
Heat rate—Btu/kWhfossil units, electric fuel, HHV
First online—
Monthly net generation
EIA-923, all units at the plant. Net of station use; storage can go negative.
FinalPreliminary
Capacity factor by year
Net MWh ÷ (summer MW × hours), primary-fuel units. Each year uses that year's EIA-860 ratings; the hollow dot is the latest 12 months.
Heat rate by year
Electric fuel MMBtu × 1000 ÷ net MWh (Btu/kWh, HHV), fossil units only; CT + CA counted as one combined-cycle block.
Annual data table
| Year | Net GWh | Capacity factor | Heat rate (Btu/kWh) |
|---|---|---|---|
| 2015 | 0 | 0.0% | 10,714 |
| 2016 | 3.3 | 12.7% | 11,391 |
| 2017 | 9.5 | 18.7% | 11,182 |
| 2018 | 8.7 | 17.5% | 12,292 |
| 2019 | 6 | 15.0% | 12,988 |
| 2020 | 4.5 | 13.7% | 12,651 |
| 2021 | 4.3 | 13.2% | 15,333 |
| 2022 | 5.7 | 17.1% | 11,203 |
| 2023 | 2.3 | 6.8% | 12,916 |
| 2024 | 0 | 0.0% | — |
Generators
EIA-860 (annual) with EIA-860M updates through Sep 2026. EIA-923 reports generation by plant, prime mover and fuel, not by unit, so unit-level output isn't shown.
| Gen ID | Technology | Prime mover | Nameplate MW | Summer MW | Online | Status | Planned retirement | OEM / model |
|---|---|---|---|---|---|---|---|---|
| A1 | Landfill Gas | IC | 0.3 | 0.3 | Oct 2016 | Retired Jun 2024 | — | coming soon |
| A2 | Landfill Gas | IC | 0.3 | 0.3 | Oct 2016 | Retired Jun 2024 | — | coming soon |
| A3 | Landfill Gas | IC | 0.3 | 0.3 | Oct 2016 | Retired Jun 2024 | — | coming soon |
| A4 | Landfill Gas | IC | 0.3 | 0.3 | Oct 2016 | Retired Jun 2024 | — | coming soon |
| A5 | Landfill Gas | IC | 0.3 | 0.3 | Oct 2016 | Retired Jun 2024 | — | coming soon |
| A6 | Landfill Gas | IC | 0.3 | 0.3 | Oct 2016 | Retired Jun 2024 | — | coming soon |
| B1 | Landfill Gas | IC | 0.3 | 0.3 | Nov 2016 | Retired Jun 2019 | — | coming soon |
| B2 | Landfill Gas | IC | 0.3 | 0.3 | Nov 2016 | Retired Jun 2019 | — | coming soon |
| B3 | Landfill Gas | IC | 0.3 | 0.3 | Nov 2016 | Retired Jun 2019 | — | coming soon |
| B4 | Landfill Gas | IC | 0.3 | 0.3 | Nov 2016 | Retired Jun 2019 | — | coming soon |
| B5 | Landfill Gas | IC | 0.3 | 0.3 | Nov 2016 | Retired Jun 2019 | — | coming soon |
| B6 | Landfill Gas | IC | 0.3 | 0.3 | Nov 2016 | Retired Jun 2019 | — | coming soon |
| C1 | Landfill Gas | IC | 0.3 | 0.3 | Dec 2015 | Retired Jun 2024 | — | coming soon |
| C2 | Landfill Gas | IC | 0.3 | 0.3 | Dec 2015 | Retired Jun 2024 | — | coming soon |
| C3 | Landfill Gas | IC | 0.3 | 0.3 | Dec 2015 | Retired Jun 2024 | — | coming soon |
| C4 | Landfill Gas | IC | 0.3 | 0.3 | Dec 2015 | Retired Jun 2024 | — | coming soon |
| C5 | Landfill Gas | IC | 0.3 | 0.3 | Dec 2015 | Retired Jun 2024 | — | coming soon |
| C6 | Landfill Gas | IC | 0.3 | 0.3 | Dec 2015 | Retired Jun 2024 | — | coming soon |
Owner / operator
Operator: Ingenco Renewable Development, LLC. Ownership shares by in-service nameplate MW (EIA-860 Schedule 4; units not listed there are wholly owned by the operator).
Nearby plants
Within 80 km.
| Wolf Hills Energy | 285 MW | 7.8 km |
| South Holston | 39 MW | 10 km |
| Wilbur | 11 MW | 29 km |
| Watauga | 58 MW | 29 km |
| Boone Dam | 106 MW | 31.9 km |
| SR Gray | 6 MW | 34.6 km |