Natural gasNatural Gas Fired Combustion TurbineISONEBA: ISNE
Nameplate17MWSummer 17 MW
Generators1in service
Net generation132GWh12 mo to Aug 2026
Capacity factor91%gas/coal/oil units, summer MW
Heat rate4,202Btu/kWhfossil units, electric fuel, HHV
First online2005Runs as baseload

The 12-month figures include preliminary EIA-923 months, which EIA revises. Final data runs through Dec 2025.

Monthly net generation

EIA-923, all units at the plant. Net of station use; storage can go negative.
FinalPreliminary
0510GWh201220132014201520162017201820192020202120222023202420252026

Capacity factor by year

Net MWh ÷ (summer MW × hours), gas/coal/oil units. Each year uses that year's EIA-860 ratings; the hollow dot is the latest 12 months.
0%25%50%75%2012201420162018202020222024202691.3% · 12 mo

Heat rate by year

Electric fuel MMBtu × 1000 ÷ net MWh (Btu/kWh, HHV), fossil units only; CT + CA counted as one combined-cycle block.
2,5005,0007,50010,00012,500201220142016201820202022202420264,202 Btu/kWh · 12 mo
Annual data table
YearNet GWhCapacity factorHeat rate (Btu/kWh)
2012114.189.0%11,723
201311892.3%11,716
2014117.591.9%11,707
2015109.885.8%11,718
2016118.592.4%4,226
2017118.993.0%4,216
2018120.294.0%4,214
2019117.491.8%4,220
2020118.592.4%4,215
2021119.593.4%4,208
2022121.795.1%4,203
2023123.785.6%4,202
2024133.392.0%4,203
2025133.492.3%4,226

Fuel capability

Gas-fired turbines (CT/GT/CA/CS) that can also burn liquid fuel. EIA-860 Schedule 3 for capability, EIA-923 for actual burn.
StatusListed in EIA-860, no liquid burn in 36 months
Liquid fuel burned · 36 mo0 MMBtu
Last month with liquid burn—
Switch while operatingYes
Net summer MW on gas16
Net summer MW on oil16
Time gas → oilup to 1 h (EIA 1H)
Time oil → gasup to 1 h (EIA 1H)

Generators

EIA-860 (annual) with EIA-860M updates through Sep 2026. EIA-923 reports generation by plant, prime mover and fuel, not by unit, so unit-level output isn't shown.
Gen IDTechnologyPrime moverNameplate MWSummer MWOnlineStatusPlanned retirementOEM / model
TG-1Natural Gas Fired Combustion TurbineGT16.516.5Apr 2005Operating—coming soon

Owner / operator

Operator: Rand Whitney Containerboard L.P.. Ownership shares by in-service nameplate MW (EIA-860 Schedule 4; units not listed there are wholly owned by the operator).
Rand Whitney Containerboard L.P.100.0%17 MW

Nearby plants

Within 80 km.
Fort Hill 1, 2, 3 & 410 MW3.5 km
Montville Station495 MW4 km
Covanta Southeastern Connecticut Company18 MW6.1 km
Subase Microgrid Project7 MW7.2 km
Naval Sub Base New London Fuel Cell7 MW7.2 km