← Back to map

Renewable Energy Services of Ohio

Erie County, Ohio · EIA plant ID 57249 · Operator: North American -- Erie, LLC
OtherLandfill GasMISOBA: PJM
Nameplate2MWSummer 2 MW
Generators2in service
Net generation10GWh12 mo to Dec 2025
Capacity factor47%other units, summer MW
Heat rate—thermal plants only
First online2010

Monthly net generation

EIA-923, all units at the plant. Net of station use; storage can go negative.
FinalPreliminary
00.511.5GWh20102012201420162018202020222024

Capacity factor by year

Net MWh ÷ (summer MW × hours), other units. Each year uses that year's EIA-860 ratings; the hollow dot is the latest 12 months.
0%25%50%75%20102012201420162018202020222024202647.4% · 12 mo

Heat rate by year

Electric fuel MMBtu × 1000 ÷ net MWh (Btu/kWh, HHV), fossil units only; CT + CA counted as one combined-cycle block.
Heat rate applies to fuel-burning (thermal) units only.
Annual data table
YearNet GWhCapacity factorHeat rate (Btu/kWh)
20108.782.3%—
201111.984.7%—
20121285.3%—
201310.273.0%—
201412.674.6%—
20151257.2%—
201615.673.9%—
201716.377.4%—
201817.583.0%—
201918.587.9%—
202017.482.6%—
202117.382.3%—
202214.267.4%—
202311.153.0%—
202410.549.6%—
20251047.4%—

Generators

EIA-860 (annual) with EIA-860M updates through Sep 2026. EIA-923 reports generation by plant, prime mover and fuel, not by unit, so unit-level output isn't shown.
Gen IDTechnologyPrime moverNameplate MWSummer MWOnlineStatusPlanned retirementOEM / model
GEN1Landfill GasIC1.61.6Apr 2010Operating—coming soon
GEN2Landfill GasIC0.80.8Aug 2014Operating—coming soon

Owner / operator

Operator: North American -- Erie, LLC. Ownership shares by in-service nameplate MW (EIA-860 Schedule 4; units not listed there are wholly owned by the operator).
North American -- Erie, LLC100.0%2 MW

Nearby plants

Within 80 km.
Monroeville RTO BTM3 MW13.6 km
Monroeville Solar3 MW14.9 km
Wheatsborough Solar125 MW18.7 km
Firelands Wind—20.4 km
West Lorain556 MW30 km
Clyde Peaking Engine10 MW30.7 km