← Back to map

Emporia Energy Center

Lyon County, Kansas · EIA plant ID 56502 · Operator: Westar Energy Inc
Natural gasNatural Gas Fired Combustion TurbineSPPBA: SWPP
Nameplate730MWSummer 669 MW
Generators7in service
Net generation658GWh12 mo to Aug 2026
Capacity factor11%gas/coal/oil units, summer MW
Heat rate10,921Btu/kWhfossil units, electric fuel, HHV
First online2008Runs as peaking

The 12-month figures include preliminary EIA-923 months, which EIA revises. Final data runs through Dec 2025.

Monthly net generation

EIA-923, all units at the plant. Net of station use; storage can go negative.
FinalPreliminary
050100150200GWh2008201020122014201620182020202220242026

Capacity factor by year

Net MWh ÷ (summer MW × hours), gas/coal/oil units. Each year uses that year's EIA-860 ratings; the hollow dot is the latest 12 months.
0%10%20%201020152020202511.2% · 12 mo

Heat rate by year

Electric fuel MMBtu × 1000 ÷ net MWh (Btu/kWh, HHV), fossil units only; CT + CA counted as one combined-cycle block.
10,00011,00012,000201020152020202510,921 Btu/kWh · 12 mo
Annual data table
YearNet GWhCapacity factorHeat rate (Btu/kWh)
2008198.512.0%10,874
2009435.77.8%11,144
2010373.36.4%11,032
2011438.27.5%10,956
2012545.99.4%10,834
20132925.2%11,597
2014271.64.8%11,930
2015251.24.4%11,638
20163345.9%11,265
2017284.45.0%11,611
2018528.19.3%10,995
2019701.412.4%10,634
2020386.36.7%11,680
2021311.85.5%11,694
2022350.86.1%12,370
20231,212.621.2%11,091
20241,548.127.0%10,730
2025584.710.0%10,996

Generators

EIA-860 (annual) with EIA-860M updates through Sep 2026. EIA-923 reports generation by plant, prime mover and fuel, not by unit, so unit-level output isn't shown.
Gen IDTechnologyPrime moverNameplate MWSummer MWOnlineStatusPlanned retirementOEM / model
1Natural Gas Fired Combustion TurbineGT5442.8Jun 2008Operating—coming soon
2Natural Gas Fired Combustion TurbineGT5444.4Jun 2008Operating—coming soon
3Natural Gas Fired Combustion TurbineGT5444.3Jun 2008Operating—coming soon
4Natural Gas Fired Combustion TurbineGT5443.9Jun 2008Operating—coming soon
5Natural Gas Fired Combustion TurbineGT171.4166Jun 2008Operating—coming soon
6Natural Gas Fired Combustion TurbineGT171.4161.4Feb 2009Operating—coming soon
7Natural Gas Fired Combustion TurbineGT171.4166Feb 2009Operating—coming soon

Owner / operator

Operator: Westar Energy Inc. Ownership shares by in-service nameplate MW (EIA-860 Schedule 4; units not listed there are wholly owned by the operator).
Westar Energy Inc100.0%730 MW

Nearby plants

Within 80 km.
Reading Wind Project200 MW9.3 km
Americus1 MW13.9 km
Thunderbird Generator (Tbird)1 MW16.6 km
Osage City15 MW29.3 km
Waverly Wind Farm LLC199 MW30.3 km
Osage City Solar2 MW30.8 km