← Back to map

Bristol Myers Squibb New Brunswick

Middlesex County, New Jersey · EIA plant ID 54829 · Operator: Bristol-Myers Squibb Co
Natural gasNatural Gas Fired Combustion TurbineNatural Gas Steam Turbine⛽ Dual-fuelPJMBA: PJM
Nameplate11MWSummer 9 MW
Generators2in service
Net generation55GWh12 mo to Aug 2026
Capacity factor67%gas/coal/oil units, summer MW
Heat rate4,859Btu/kWhfossil units, electric fuel, HHV
First online1992Runs as baseload

The 12-month figures include preliminary EIA-923 months, which EIA revises. Final data runs through Dec 2025.

Monthly net generation

EIA-923, all units at the plant. Net of station use; storage can go negative.
FinalPreliminary
0510GWh2001200420062008201020122014201620182020202220242026

Capacity factor by year

Net MWh ÷ (summer MW × hours), gas/coal/oil units. Each year uses that year's EIA-860 ratings; the hollow dot is the latest 12 months.
0%50%100%2005201020152020202567.4% · 12 mo

Heat rate by year

Electric fuel MMBtu × 1000 ÷ net MWh (Btu/kWh, HHV), fossil units only; CT + CA counted as one combined-cycle block.
4,6004,8005,0005,200200520102015202020254,859 Btu/kWh · 12 mo
Annual data table
YearNet GWhCapacity factorHeat rate (Btu/kWh)
200177.3——
200274.8——
200475.291.1%4,871
200578.595.3%4,871
200664.778.6%4,842
20075769.2%4,770
200847.157.1%4,871
200949.159.6%4,816
201049.860.5%4,870
201140.148.7%5,204
201250.561.2%4,979
201349.560.1%4,971
201453.865.3%4,961
20155566.8%4,930
201659.271.8%4,856
201764.978.8%4,838
20185566.8%4,874
201944.654.2%4,867
202052.263.2%4,852
202156.869.0%4,886
202255.767.6%4,877
202357.870.2%4,842
202456.167.9%4,838
20255668.0%4,877

Fuel capability

Gas-fired turbines (CT/GT/CA/CS) that can also burn liquid fuel. EIA-860 Schedule 3 for capability, EIA-923 for actual burn.
StatusLikely still dual fuel
Liquid fuel burned · 36 mo1,595 MMBtu
Last month with liquid burnFeb 2026
Switch while operatingNo
Net summer MW on gas9
Net summer MW on oil9
Time gas → oilup to 1 h (EIA 1H)
Time oil → gasup to 1 h (EIA 1H)

Generators

EIA-860 (annual) with EIA-860M updates through Sep 2026. EIA-923 reports generation by plant, prime mover and fuel, not by unit, so unit-level output isn't shown.
Gen IDTechnologyPrime moverNameplate MWSummer MWOnlineStatusPlanned retirementOEM / model
GEN1Natural Gas Fired Combustion TurbineGT9.58.8Jul 1992Operating—coming soon
GEN2Natural Gas Steam TurbineST10.6Aug 1999Operating (Standby / backup)—coming soon

Owner / operator

Operator: Bristol-Myers Squibb Co. Ownership shares by in-service nameplate MW (EIA-860 Schedule 4; units not listed there are wholly owned by the operator).
Bristol-Myers Squibb Co100.0%11 MW

Nearby plants

Within 80 km.
Rutgers Cook Douglass Lot 97 & 98a1 MW0.9 km
Milltown Onsite BESS—2.7 km
GSPP Onyx New Brunswick LLC1 MW3.1 km
Highland Park Borough Solar1 MW3.4 km
Franklin Solar 2 LLC Community Solar4 MW4.1 km
Silver Lake Solar Farm2 MW4.5 km