Bethlehem Energy Center

Albany County, New York · EIA plant ID 2539 · Operator: Generation Bridge II New York LLC
Natural gasNatural Gas Fired Combined CycleNYISOBA: NYIS
Nameplate893MWSummer 813 MW
Generators4in service
Net generation3,315GWh12 mo to Aug 2026
Capacity factor47%gas/coal/oil units, summer MW
Heat rate11,110Btu/kWhfossil units, electric fuel, HHV
First online2005Runs as baseload

The 12-month figures include preliminary EIA-923 months, which EIA revises. Final data runs through Dec 2025.

Monthly net generation

EIA-923, all units at the plant. Net of station use; storage can go negative.
FinalPreliminary
-2000200400GWh2001200320052007200920112013201620182020202220242026

Capacity factor by year

Net MWh ÷ (summer MW × hours), gas/coal/oil units. Each year uses that year's EIA-860 ratings; the hollow dot is the latest 12 months.
0%25%50%75%2005201020152020202546.6% · 12 mo

Heat rate by year

Electric fuel MMBtu × 1000 ÷ net MWh (Btu/kWh, HHV), fossil units only; CT + CA counted as one combined-cycle block.
6,0008,00010,00012,0002005201020152020202511,110 Btu/kWh · 12 mo
Annual data table
YearNet GWhCapacity factorHeat rate (Btu/kWh)
2001340.4——
2002135——
2003101.53.2%12,038
2004278.68.7%11,046
200516.90.6%11,891
20062,330.135.5%7,173
20073,306.650.4%7,196
20082,83543.1%7,645
20093,493.153.4%7,526
20104,227.463.9%7,411
20114,239.564.2%7,105
20124,903.773.8%7,093
20133,951.759.8%7,079
20144,286.763.2%7,084
20155,152.777.7%7,073
20165,202.476.6%7,071
20175,303.778.3%7,014
20185,142.174.4%7,020
20194,544.563.7%7,036
20204,975.769.3%6,972
20215,305.374.3%6,966
20224,262.559.7%7,104
20234,357.961.0%10,009
20243,638.550.8%10,820
20253,431.948.2%11,012

Fuel capability

Gas-fired turbines (CT/GT/CA/CS) that can also burn liquid fuel. EIA-860 Schedule 3 for capability, EIA-923 for actual burn.
StatusListed in EIA-860, no liquid burn in 36 months
Liquid fuel burned · 36 mo0 MMBtu
Last month with liquid burn—
Switch while operatingYes
Net summer MW on gas507
Net summer MW on oil507
Time gas → oilunknown (EIA UNK)
Time oil → gasunknown (EIA UNK)

Generators

EIA-860 (annual) with EIA-860M updates through Sep 2026. EIA-923 reports generation by plant, prime mover and fuel, not by unit, so unit-level output isn't shown.
Gen IDTechnologyPrime moverNameplate MWSummer MWOnlineStatusPlanned retirementOEM / model
5Natural Gas Fired Combined CycleCT194.3169.1Jul 2005Operating—coming soon
6Natural Gas Fired Combined CycleCT194.3169.1Jul 2005Operating—coming soon
7Natural Gas Fired Combined CycleCT194.3169.1Jul 2005Operating—coming soon
8Natural Gas Fired Combined CycleCA310.2305.4Jul 2005Operating—coming soon
1Natural Gas Steam TurbineST10090Oct 1952Retired Dec 2005—coming soon
2Natural Gas Steam TurbineST10090Nov 1952Retired Dec 2005—coming soon
3Natural Gas Steam TurbineST10091Sep 1953Retired Dec 2005—coming soon
4Natural Gas Steam TurbineST10094Aug 1954Retired Dec 2005—coming soon

Owner / operator

Operator: Generation Bridge II New York LLC. Ownership shares by in-service nameplate MW (EIA-860 Schedule 4; units not listed there are wholly owned by the operator).
Generation Bridge II New York LLC100.0%893 MW

Nearby plants

Within 80 km.
Bethlehem5 MW2.7 km
Empire Generating Co LLC654 MW3.6 km
Rensselaer Cogen88 MW3.6 km
Castleton Energy Center72 MW6.5 km
Albany Medical Ctr Cogen Plant4 MW6.9 km
NY Selkirk S Albany RD - Hemlock Hills S5 MW7.8 km