← Back to map

Thomas Fitzhugh

Franklin County, Arkansas · EIA plant ID 201 · Operator: Arkansas Electric Coop Corp
Natural gasNatural Gas Fired Combined CycleNatural Gas Fired Combustion Turbine⛽ Dual-fuelSPPBA: SWPP

69 MW under construction (Natural Gas Fired Combustion Turbine), first expected Nov 2026 · EIA-860M

Nameplate256MWSummer 209 MW
Generators3in service · 69 MW building
Net generation472GWh12 mo to Dec 2025
Capacity factor33%gas/coal/oil units, summer MW
Heat rate8,984Btu/kWhfossil units, electric fuel, HHV
First online1963Runs as intermediate

Monthly net generation

EIA-923, all units at the plant. Net of station use; storage can go negative.
FinalPreliminary
020406080GWh2001200320052007200920112013201520172019202120232025

Capacity factor by year

Net MWh ÷ (summer MW × hours), gas/coal/oil units. Each year uses that year's EIA-860 ratings; the hollow dot is the latest 12 months.
0%10%20%30%2005201020152020202533.3% · 12 mo

Heat rate by year

Electric fuel MMBtu × 1000 ÷ net MWh (Btu/kWh, HHV), fossil units only; CT + CA counted as one combined-cycle block.
8,0009,00010,00011,000200520102015202020258,984 Btu/kWh · 12 mo
Annual data table
YearNet GWhCapacity factorHeat rate (Btu/kWh)
200169.1——
200222.5——
200373.54.9%10,277
2004271.8%10,950
2005199.213.3%9,119
2006268.217.9%8,947
2007112.27.5%9,275
200835.12.3%9,703
200961.84.3%9,573
201082.55.7%9,648
201193.46.5%9,361
2012114.57.9%9,377
20134.80.3%10,546
201426.11.8%9,441
201576.45.4%8,634
2016255.918.0%8,872
2017145.310.2%9,480
2018272.919.2%9,174
2019254.918.0%9,324
2020424.929.9%8,765
2021242.317.1%8,994
2022477.633.7%8,706
2023404.528.5%8,803
2024484.434.0%8,563
2025472.333.3%8,984

Fuel capability

Gas-fired turbines (CT/GT/CA/CS) that can also burn liquid fuel. EIA-860 Schedule 3 for capability, EIA-923 for actual burn.
StatusLikely still dual fuel
Liquid fuel burned · 36 mo11,403 MMBtu
Last month with liquid burnDec 2025
Switch while operatingYes
Net summer MW on gas162
Net summer MW on oil142
Time gas → oilup to 1 h (EIA 1H)
Time oil → gasup to 1 h (EIA 1H)

Generators

EIA-860 (annual) with EIA-860M updates through Sep 2026. EIA-923 reports generation by plant, prime mover and fuel, not by unit, so unit-level output isn't shown.
Gen IDTechnologyPrime moverNameplate MWSummer MWOnlineStatusPlanned retirementOEM / model
1Natural Gas Fired Combined CycleCA5961May 1963Operating—coming soon
2Natural Gas Fired Combined CycleCT126101Dec 2002Operating—coming soon
3Natural Gas Fired Combustion TurbineGT71.246.5May 2026Operating—coming soon
4Natural Gas Fired Combustion TurbineGT69.346.5planned Nov 2026Under construction—coming soon

Owner / operator

Operator: Arkansas Electric Coop Corp. Ownership shares by in-service nameplate MW (EIA-860 Schedule 4; units not listed there are wholly owned by the operator).
Arkansas Electric Coop Corp100.0%256 MW

Nearby plants

Within 80 km.
Ozark100 MW1.4 km
Arkansas Valley1 MW6 km
City of Paris Solar2 MW19.1 km
Branch Solar Farm5 MW20.5 km
Scenic Hill Solar III5 MW26.2 km
City of Clarksville10 MW26.2 km